← All articles & guides

A SIP channel effectively corresponds to one active call to or from the public telephone network. You do not need one channel per user or telephone number; you need enough capacity for the calls that may be in progress at the same time, with reasonable headroom for peaks.

Users, numbers and channels: three different quantities

A business may have 40 employees and 20 telephone numbers but need only 8 or 10 concurrent external calls. Users indicate how many people use telephony. Numbers, or DIDs, indicate where the business can receive calls. Channels determine how many external calls can be active simultaneously.

Internal calls between users on the same PBX generally do not consume a SIP Trunk channel. A call to a mobile or landline, or an incoming call from the public network, uses trunk capacity. Some scenarios, such as forwarding an incoming call to another external number, may use more than one call leg and must be checked during design.

How to make a practical calculation

The best approach is to use actual call data. Review peak periods and identify how many calls were active simultaneously. CDRs from the existing PBX or provider can give a much clearer picture than a simple ratio of “one channel per X users”.

If historical data is unavailable, start with how the business operates: how many people regularly speak with customers, are there sales teams or call queues, are outbound calls made in bulk, and are there seasonal peaks or multiple branches? Then add headroom so that a normal increase in traffic does not result in busy lines.

Four factors that change capacity requirements

  • Queues and Contact Center: more calls may be waiting or being handled simultaneously.
  • Sales and outbound teams: outgoing activity can cause a sudden increase in usage.
  • Forwarding to mobiles or external field teams: this may use additional call legs.
  • Fallback routing and secondary sites: the design must consider what happens when the normal call path changes.

Base capacity purchases on evidence

Excess capacity increases recurring costs unnecessarily. Insufficient capacity leads to failed or busy calls when the business needs telephony most. The right approach combines initial sizing, monitoring of actual usage and the ability to adjust when volumes or working practices change.

At UniLoud, SIP Trunk and UniPBX design explicitly distinguishes users, numbers and concurrent calls. This allows the package to reflect how the business operates rather than a general assumption.

Frequently asked questions

I have 30 extensions. Do I need 30 channels?

Not necessarily. You need channels for external calls that will be active simultaneously. Depending on usage, 30 users may need significantly less or more capacity in practice.

Can one telephone number receive multiple calls?

Yes, if the service, PBX and available capacity allow it. The telephone number and the number of concurrent calls are different quantities.

What happens if I reach the limit?

New calls may fail or receive a busy signal or rejection, depending on configuration. That is why peak usage must be monitored and headroom planned.

Related services and guides

Discuss your next step with UniLoud

Send us your user count, sites and, if available, a CDR sample. We will help you calculate the capacity that suits your call traffic.

Contact UniLoud